Plymouth EFW (Energy From Waste)

This facility will provide South West Devon with one of the most efficient energy from waste plants in Europe. For this large frost protection application, ESH split the project into two separate systems:

  • System one was designed, supplied and installed with type VC constant wattage heating cable onto the range pipework, the manifolds and gel skid pipe, incoming feed, deluge and cannon feed pipes.
  • The second system was for the frost protection of 400mm NB steel pipework associated with two hose reels. ESH supplied and installed type ESRS self regulating cable in order to prevent the pipework temperature dropping below +5°C.


Friday, 13 March 2015

Robert Sanderson & Sons Ltd, Hull

ESH supplied and install a trace heating system to temperature maintain a large HCA storage tank at +36°C in a minimum ambient of -20°C. The system, within a Zone II Hazardous Area, required over 150 metres of type SCBX ATEX approved constant wattage heating cable. 

Monday, 9 March 2015

Solvay Ltd, Oldbury

ESH were contracted to supply and install constant wattage heating cable to repair a damaged trace heating circuit. The 2" and 3" NB pipework containing PPA needed to be temperature maintained at +100°C. 

Thursday, 5 March 2015

Orley Farm School, Harrow

ESH supplied and installed a trace heating system to provide frost protection to two runs of BCWS pipework. Type VCBOJ constant wattage heating cable was installed onto the external metal pipes and controlled using STCI thermostats.

Friday, 27 February 2015

Flint Ink UK Ltd, Wolverhampton

A local project and a site we have done work for in previous years. ESH were contracted to supply and install a trace heating system to maintain steel pipework and two tanks at a temperature of +70ºC. The tanks comprised of a holding tank and a pre-mix tank, both 2.2m diameter and 3.5m tall. In total the system required over 300 metres of type SCB30/2 constant wattage heating cable.

Monday, 23 February 2015

Stepan UK, Cheshire

The project scope here was to design, supply and install a trace heating system to temperature maintain three sections of pipework at +30ºC and +10ºC respectively. Almost 500 metres of type FBTBOJ20/2 self regulating heating cable was installed and controlled using multiple digital thermostats and control panels.

Tuesday, 17 February 2015

University Hospital Of Wales, Cardiff

Supplied and installed a trace heating system to temperature maintain hot water pipework at a minimum of +55°C. Type H2OWAT55 self regulating heating cable was straight traced onto the copper pipework.